SHANGYU POWER CHINA is one of the professional 208V Low voltage UPS manufacturers and suppliers in China, providing easy-maintainable and durable 208V Low voltage UPS worldwide. Not only do we have our own factory, but we also offer competitive prices. Our products have obtained CE certification, and we also provide customized services. You are welcome to place an order.

Send Inquiry
Product Description

A Professional Manufacturer of 208V Low voltage UPS SHANGYU POWER CHINA® is a professional manufacturer of uninterruptible power supplies. We are located in Shenzhen and have a registered capital of $2.3 million and a production area of 25,000 square meters. We have our own R&D team with more than 30 R&D engineers with more than 20 patents, and put 15% sales revenue each year to R&D research.With strict quality control system and all our UPS products meet with the CE,TLC, CQC and more certificates.Our aim is continuously to offer our customer stable and reliable, clean and high-efficiency power.welcome to inquiry.

You can rest assured to buy 208V Low voltage UPS from our factory. This SHANGYU POWER CHINA® 6KVA LCD Single Phase Low frequency ups is the latest invention of high-quality ups products, which comply with CE, ROHS, IEC, BS,UL,TUV, SAA standard and comes with a 2-year warranty, . The SHANGYU POWER CHINA® 6KVA LCD Single Phase Low frequency ups is made of metal+ PCBA, which has been designed to meet most demanding power requirements, being easy to install and maintain. It combines latest high energy efficiency technology and high power density technology,achieving small size, stable performance and price competitive for UPS products.

SHANGYU POWER CHINA® GP11 series Single Phase Low frequency ups Parameter (Specification)

208V Low voltage UPS specification table 1
ModelHP3310HHP3315HHP3320HHP3330HHP3340HHP3360HHP3380HHP33100HHP33120HHP33160HHP33200H
Capacity10KVA/9KW15KVA/13.5KW20KVA/18KW30KVA/27KW40KVA/36KW60KVA/54KW80KVA/72KW100KVA/90KW120KVA/108KW160KVA/144KW200KVA/180KW
I/O mode3/3 phase
Work modeTrue double conversion online ups
Installation typeTower
INPUT—
Voltage380/400/415VAC
Voltage RangeFull load: phase voltage 190-276v line voltage 330-478v (-15%, +20%), half load: phase voltage 116-276/line voltage 201-478 (-50%, +20%)Full load: phase voltage 190-330 line voltage 276-478V (-15%, +20%), 116/201-276/478V (-50%, +20%) at 50% load
Frequency Range40~72Hz
Power Factor≥0.99
BreakerStandard (in-built)Optional (external distribution cabinet(Input, output, maintenance bypass in one))
Breaker Capacity40A/3P40A/3P40A/3P63A/3P100A/3P125A/3P150A/3P250A/3P250A/3P400A/3P400A/3P
OUTPUT—
Voltage380/400/415VAC:≤±1%
Frequency Range50/60Hz±1%
Power Factor0.9
Transfer Time0ms
Overload100%≤load<110, 60mins, 110%≤load≤125%,10mins, 125%load≤150%, 1mins, load≥150%, transfer to bypass immediately after 500 ms100%≤load≤105%, long-term , 106%≤load≤125%, 10mins, 125%load≤150%, 1min, load≥150%, transfer to bypass immediately after 150ms
BreakerStandard (in-built)Optional (external distribution cabinet(Input, output, maintenance bypass in one))
Breaker capacity40A/3P40A/3P40A/3P63A/3P100A/3P125A/3P160A/3P250A/3P250A/3P400A/3P400A/3P
BATTERY—
Battery TypeVALR battery
Battery Voltage384VDC(384V~480V adjustable),Standard 32pcs(32/34/36/38/40pcs adjustable)Standard 480V(432V/456V/480 adjustable),40pcs(36/38/40/pcs adjustable)
Charging Current3.5(5.3AMAX)4A(8AMAX)5A(10.6AMAX)6A(16AMAX)8A(24AMAX)10A (40AMAX)20A(80AMAX)
Charging Current adjustableSupport
Breaker capacityNo
Cold StartNo support
No battery power-on functionSupport
STANDARDS—
Efficiency95%
ECO mode98%
SafetyEN 62040-1
EMCEN 62040-2
CertificateTLC/CECP/CE/RoHS
IPIP20
Function—
EPOSupport
ECOSupport
Cold StartSupport
BypassStandard (in-built)Optional (external distribution cabinet(Input, output, maintenance bypass in one))
Bypass breaker3P/40A3P/40A3P/40A3P/63A100A/3P3P/125A3P/160A250A/3P250A/3P400A/3P400A/3P
Parallel NO.4pcs4pcs
Parallel shared battery packNo supportNo support
Communication—
Control PanelLCD+LED display
Communication portStandard RS232, optional SNMP card, AS400 relay card
SNMP Serial NO.SMP-00204-00
PHYSICAL—
W*D*H500*700*1020(mm)600*800*1875(mm)600*800*1875(mm)600*830*1875
Net Weight(KG)758896202245311457
Noise Level(less1m)<55dB<62dB<65dB<65dB<70dB
ENVIRONMENT—
Operation temperatureRecommended temperature UPS:0-40℃;Battery:20-25℃
Operation Humidity5%-95%,No condensation
Storage temperature-15-55℃
Storage relative humidity5%-95%,No condensation
Altitude<1000m

SHANGYU POWER CHINA® GP11 series 6KVA Single Phase Low frequency ups Feature And Application

SHANGYU POWER CHINA® GP11 series 6KVA Single Phase Low frequency ups 1-40KVA ups

Model No.:GP1101K/GP1102K/GP1103K/GP1106K/GP1110K/GP1115K/

GP1120K/GP1130K/GP1140K

UPS power range: 1KVA~40KVA

Features:

--Standard output isolation transformer.Optional input isolation transformer

-PM2.1 technology insect proof waterproof, noise and dustproof

-Support 3 parallel functions,Optional N+X parallel redundancy

-Adjustable charging current,such as 8A for long-run models

--Excellent industrial environmental protection performance

-True double conversion DSP technology, high reliability

-Eco mode operation for energy saving(ECO)

-Output adjustable 200/208/220/230/240VAC

-Dust gauze Level between IP20-IP51

-Emergency power off function(EPO)

-Generator compatible

Application:

Industrial environments, medical facilities, laboratory equipment, etc. are key equipment for power supply and protection.

Application

Servers.

Educational Institutes.

BFS

Healthcare Systems.

Telecommunication Equipments.

Small & Medium Data Centers.

CNC Machines.

Pharmaceutical Appliances.

X-ray Machines.

Industrial Facilities.

SHANGYU POWER CHINA® 500KVA LCD 3/3 Phase industrial ups Details

When compare with peers, SHANGYU POWER CHINA® 3/3 Phase industrial ups advantages as below:

1. Other peers can only switch 70% of the load instantaneously without load, while SHANGYU POWER CHINA can switch full load instantaneously without load, and has a strong load carrying capacity for non-linear loads

2. Other peers are single DSP control mode, while SHANGYU POWER CHINA is dual DSP control mode

3. The floating charging of other peers cannot be automatically converted, but the SHANGYU POWER CHINA is automatically switching to floating charging, and the battery is regularly self-tested

4. Other peers can parallel 2-4 units, while SHANGYU POWER CHINA can parallel 6-8 units

5. Other counterparts have a single auxiliary power supply system, while SHANGYU POWER CHINA is a redundant dual auxiliary power supply system with auxiliary power fault protection

6. SHANGYU POWER CHINA supports double busbar system, busbar overvoltage protection, other peers do not support it

7. Regarding the nonlinear load waveform distortion, the SHANGYU POWER CHINA parameter and the actual value are both THDV≤4%-5%, while other peers show THDV≤5% on the parameter, but the actual THDV≤6%-8%

8. Other peers use static switches of relays, while SHANGYU POWER CHINA uses static switches of SCR thyristors, which have stronger impact resistance

9. Quality is our culture. 90% of the components of SHANGYU POWER CHINA UPS use Fairchild, Infineon, Onsemi, TI, NXP and other well-known brand A grade materials to ensure their good performance. More importantly, the fault detection rate of SHANGYU POWER CHINA UPS is ≦0.2% -0.5%, while the fault detection rate of other peers is ≦0.5%-1%.

10. SHANGYU POWER CHINA low frequency industrial UPS can be used for 25 years above, and it will fault after 5-7 years usually; while the low frequency industrial UPS of the peers can be used for 15 years above, usually after 2-3 years, it will fault. The operating cost of SHANGYU POWER CHINA ups is far lower than the peers everyday.

208V Low voltage UPS specification table 2
ItemSHANGYU POWER CHINA&reg;Other Peers
Without loadswitch full load instantaneouslyswitch 70% load instantaneously
Control modedual DSPsingle DSP
Static switchesSCR thyristorsrelays
Floating charging switchAutomatically,battery self-testedcannot be automatically converted
Parallel function6-8 units2-4 units
THDV≤4%-5%THDV≤6%-8%(show THDV≤5%)
Bus-bar systemsupportsnot support
Fault detection rate≦0.2% -0.5%≦0.5%-1%
Machine life25-30 years20-25 years
MTBF>250000hours>175000hours
Fault happenafter 5-7 years useafter 2-3 years use